Archive for September, 2013


Home Power Generation Units and Their Impact

Home Power Generation Units and their impact

It absolutely was just one century ago that electricity was obviously a convenience instead of a necessity. Homes which in fact had electricity enjoyed a number of lights and also fewer receptacles for plugging appliances into. Electrical codes were few and those that existed weren’t widely enforced. Gradually, some great benefits of electricity were realized and by the 1930s, most homes in US cities had electricity, but rural farms and homes didn’t.
The Rural Electrification Act of 1935 was passed with the purpose of providing electricity to any homes in the USA. Multiple electricians worked along with line crews to put in electricity on farms. Most homes were provided 60 amp service that included a range circuit, a kitchen circuit, and two or three lighting circuits.

Reliance upon Electricity

Obviously, luxury hotels and manufacturing facilities were the first to embrace electricity. Hotels installed electric lighting and operated their own generators. Likewise, industry switched from steam driven equipment to electrical motors and in addition used electrical generators to produce their own electricity.
As the ability to produce electricity grew, hotels and industry gradually stopped generating their own power and relied on the newly constructed power grid instead. Electricity use spread along with other businesses and after that homes in cities and across America’s rural areas.
As electrical service was installed through the county, reliance upon electricity grew. Refrigeration that was once based on blocks of ice was largely substituted with electric refrigerators after the 1940s. Electrical lighting proved safer than oil lanterns and gas lamps, and America’s reliance upon electricity grew as each new convenience was a necessity. Virtually all the electricity originated from generators operated by the first electric utilities.

Backup Power

The electricity grid has always been susceptible to interruptions due to natural events and accidents. Weather is often the culprit behind an outage then when damage to the grid is widespread, it could take days or even weeks to fix.
Home standby and portable power generation units can supply electricity when the utility services are interrupted. They are doing more than simply supply power for the sake of convenience, they protect homes, families, and property. Today’s modern home relies on electricity for many purposes, and any one of those can spell disaster when the utility power is interrupted. A property power generation unit supplies electricity that is not really only a convenience, but has become a necessity.

Medical Equipment – Here

People who trust medical equipment are able to live at home and not in institutions because of the widespread accessibility to reliable electricity. Once the method of getting electricity is interrupted, the medical equipment fails. Home generators for backup power can supply the necessary electricity and make the apparatus operating. Generators can supply power for abbreviated periods until help arrives, or as long as the outage lasts. Home medical equipment that can run on standby generator or portable generator power includes oxygen generators, monitors, CPAP machines, and residential dialysis equipment, as well as other types of equipment.

Home Appliances

Throughout a power outage, home generators supply power for sump pumps to prevent flooding, well pumps to offer water for drinking and sanitation, and refrigerators and freezers to help keep food from spoiling.
Early 20th century homes had outdoor plumbing, passive heating systems, and windows for temperature control. Today, HVAC systems provide climate control to help keep homes warm or cool and provide adequate ventilation and the plumbing from freezing or mold from growing when the humidity is simply too high.
As reliance upon electricity is continuing to grow, our capacity to do without some has decreased proportionally. Home power generation units add the space left when power companies neglect to deliver electricity to homes that require it.

To find out more, go to: www.BackupHomePower.com

Generac Generators Updates the 20kw Standby Generator

Generac Generators Updates the 20kw Standby Generator to New Model – 6244

Generac Power Systems introduced the updated model 6244, 20kW Guardian Standby Generator using the new Evolution Controller. The favorite package previously sold under model #5875 which included the 200 Amp, Service-Entrance-Rated Smart Switch, an automatic transfer switch. The new type of the Guardian Series backup generators has been available since January in the 2013 International Builder’s Show in Vegas, Nevada.

Generac’s Guardian Series Home Standby Generators work with an automatic transfer switch the signal from supply chance to a house throughout a power outage without homeowner intervention and run on either propane (LP gas) or Gas Main, eliminating the necessity for frequent refueling.

Evolution Controller

The Evolution replaces the Nexus Controller and includes many updated features. The new interface is often a back-lit membrane keypad to demonstrate generator status instantly. Other new features go beyond the cosmetic. The live view screen still shows two lines of text and reports maintenance logs, generator status alerts, and alarms, but new functional features help house owners with better specifics of battery health, as well as alarms for that wall charger, overload, and fuse warnings to distinguish challenges before they become problems.

The new Evolution also supplies a USB port which allows a technician to update the firmware without removing the controller―a far better solution than swapping out your old Nexus controller for just one with updated programming.

Engine Upgrades

The Guardian group of generators uses Generac’s engineered overhead valve industrial engine―the only engine in the industry that was specifically made for use in standby generators. Generac has produced the engines in their standby units better to service and contains improved starting at a wide range of temperatures using the new updated model line. A redesigned fuel system eliminates the choke and contains a standard throttle body.

Guardian generators ship from the factory able to run using gas main. Conversion to LP gas has long been simple and easy and took just moments, but the new design allows conversion without tools and just has a few seconds. It is actually turning a knob.

Entire Home Power

With 20,000 watts of power, the 6244 can run many kitchen appliances including air conditioning. The Smart Switch contains a load-shedding controller which allows high-voltage appliances to operate without overloading the generator. The Smart Switch senses an overload condition and turns off high-voltage loads in order of assigned priority.

Without the additional hardware, the Smart Switch can control two air conditioning. Digging in an electric Management Module core kit allows the addition of another high-voltage device. Fully packed with four Power Management Modules (PMMs) allows the smart switch to manage when using two air conditioning and 4 additional high-voltage, high-current appliances.

Neighborhood Friendly Design

The 20kW 6244 will fit easily into any suburban neighborhood. The all-metal enclosure is powder coat painted to have an attractive appearance made from Galvaaneal steel for a long, corrosion free-life. Just 66db, it’s quieter than many central air conditioning unit units―important to keep the neighbors happy when their power is going along with their windows are open up. Placement is made easy by compliance with National Fire Protection Association codes and regulations for placement at 18 inches from the home.

Generac leads the industry with standby generators for backup home power, and now the Guardian lineup receives a well earned update.

For more info go to: www.NPSGenerac.com

Need More than a 20kw Generator can Provide

Need More than a 20kw Generator offers? A glance at Larger Units and Who Needs Them

Air-cooled standby generators top out at 20 kilowatts, that is a nothing more than 83 amperes at 240 volts. Most new homes have 200-amp service. In general, most homes avoid using how much power their service is capable of supplying, and seldom come close―most of the time. In fact, most homes don’t exceed 80 amperes apart from short periods or when large motors on air conditioners or well pumps start. From the 1940s to the 1970s, 60-ampere service was usual and 100-ampere service became common within the 1970s.

With power management features available for most residential standby generators, as well as conservative power use practices, most homes can perform comfortably on 20 kilowatts or a smaller amount of standby power.

Higher Power Requirements

Larger homes have higher power requirements. It’s not at all uncommon to need 300- and 400-amp service in large homes, along with the largest luxury homes are often given even larger electrical service. They have got multiple, high-capacity air conditioners and furnaces, and in general, larger appliances.  Power use exceeding 20 kilowatts will be the normal, everyday degree of used in these homes.

Small enterprises and manufacturing facilities are also higher users of electricity. When it comes to larger facilities, multiple standby generators can be used to produce enough standby electricity just to supply emergency systems that don’t include everyday operational requirements.

Liquid Cooled Generators

Liquid-cooled standby generators use engines comparable to those seen in cars. There is a fan-cooled radiator filled up with coolant which is pumped from the engine to cool it. As they do not count on the ambient air temperature to directly cool the engine, and also, since their air conditioning is active instead of passive, they have got less issue with overheating and give more reliable operation.

Standby generators of this type can be obtained with as much as 60 kilowatts of power for residential use, and bigger models up to 150 kilowatts for commercial use. A capacity of 60kW provides up to 250 amperes of current continuously, enough to keep most luxury homes operating without the need for judicious utilization of power.

The larger, commercial standby models will handle the requirements of most commercial facilities and can supply power to restaurants, offices, apartments, and retail facilities. Facilities which need more power can install multiple units.

Manufacturers

For residential use, Generac Power Systems manufacturers the QuietSource type of home standby generators. The QuietSource models can be purchased in 22, 27, 36 and 48 kilowatts, enough power for many larger and luxury homes. QuietSource generators include models in 240-volt single-phase,  208-volt three-phase, and 480-volt three-phase standby power.

Generac’s Commercial series of liquid-cooled standby generators include 22 to 150 kilowatt models for business or commercial use and come in 240, 208, or 480 volt models in single and three-phase configurations. Models with aluminum or steel enclosures can be obtained.

Briggs & Stratton has three models available for entire house standby power in 35, 45, and 60 kilowatts to power the most important of luxury homes during a power outage. With this sort of power available, there’s no need to forgo any one of life’s necessities or conveniences.

Considerations

Homes that count on high-demand electric appliances such as ranges, dryers, water heaters, well pumps, electric heating, and central air conditioners may need more power than an air-cooled standby generator provides without extensive management and careful using of power. These homeowners must look into a more substantial, liquid cooled generator.

Businesses and commercial operations ought to have the reliability and power advantages that larger, liquid-cooled standby generators can offer.

For more information on these great brands, please go to: www.NPSGenerac.com

20kW Standby Generator Comparison

20kw Standby Generator Comparison

Standby generators supply backup power during an outage, whether for a couple hours or maybe a few weeks after a major storm like Hurricane Sandy. Manufacturers including 20kW standby generators by the volume of continuous power they are able to provide, and not all generator ratings are equal. Briggs & Stratton, Generac, and Cummins Onan all offer standby generators that run on either LP or gas, only provide a full 20kW of power while running on LP. The generators are derated while operating on gas and can only provide up 18kW of continuous power.

Kohler generators are designed to run on either LP or NG, and so they supply the rated power for that generator. A 20kW NG standby unit will provide 20,000 watts of power, the same as the similar model that runs using LP gas.

Reserve power isn’t advertised by standby generator manufacturers, but generators provides a supplementary boost of power for a couple seconds to start large, robust motors.

Remote Options

Generac uses cellular phone texting system using Mobile Link offering to deliver status and maintenance updates for 20kW generator on any text-message-capable cell phone. Mobile Link offers web access through the computer, tablet, or mobile phone that also includes programming exercise periods or scheduling maintenance.

Cummins Onan can email updates, send maintenance requests to technicians, and permit viewing generator status from the net.

Kohler Power Systems has got the On Cue Home Generator Power Management System, which allows homeowners to watch real-time 20kW standby generator status, view and reset diagnostic codes, check status messages, and consider multiple generators on a single screen.

Warranty

All the 20kW generator manufacturers offer warranties applicable to standby power applications when a utility supply is connected. Off-grid systems not connected to the utility supply are not covered by the standard consumer warranties.

Kohler’s consumer warranty is a few years or 2000 hours. Using off-grid applications being a standby unit, they offer an 18 month/1000 hour warranty. Labor is just covered throughout the first couple of years after installation.

Generac offers a 5 year consumer warranty with complete coverage for that first couple of years, coverage only on parts in year three, and limited coverage about the alternator and engine in years 4 and 5.

Briggs & Stratton supplies a 4 year, 1600 hour limited warranty on parts and labor.
Cummins Power Systems comes with a limited consumer warranty for 5yrs or 2000 hours. Off grid applications have warranty coverage for 12 months or 1000 hours. Travel and labor are covered for that first couple of years.

For more information go to: www.NPSGenerac.com

Emergency Generators – A Must for All Residential Homeowners

Emergency Generators: Essential for All Residential Homeowners

The time when electricity in a home was obviously a luxury convenience is no longer carried out. Since the end of the 1940s, nearly every existing home in the US has been furnished with electrical power, and many jurisdictions require complete installation in new homes. Modern homes depend upon electricity for hvac, preventing ground water flooding, home alarm systems and refrigeration. Homes in rural areas also have electricity to pump water for consumption, hygiene, and sanitation.

When electrical power is lost, these essential systems will not function. Basements and crawl spaces can flood from ground-water seepage, refrigerators and freezers slowly warm and food spoils. In subfreezing temperatures, the plumbing could eventually freeze leading to broken pipes and the possibility of flooding. During extended outages, batteries in home alarm systems will fail. Individuals who depend upon medical equipment may be at increased risk whenever they do without their life support systems.

Making do without electricity can often be more than simply an inconvenience, it places the property in danger and will threaten the lives of those that depend upon the security their house provides.

Emergency Generator Protection

It is unnecessary to call a place home without electrical power after an urgent situation generator is installed.

When utility power fails, an urgent situation supply of power is able to keep essential circuits operating. The greater the generator, the harder it is able to power. Smaller standby and portable units of 5000 to 7000 kilowatts are able to keep the refrigerator and freezer cold, power a few lights, along with the sump pump and maybe the furnace when it is needed.

Larger units as much as 14 kilowatts with power management strategies will handle more appliances including well pumps, water heaters, and air conditioning, in addition to more convenience lighting and small appliances or computers.

Air cooled standby units up to 20,000 watts are for sale for larger homes or more appliances. Liquid cooled units of up 60 kilowatts will give even the most power hungry of homes with sufficient capability to keep everything running from pool pumps to jacuzzis.

Standby Emergency Generators

Portable generators can supply backup power, but they won’t do it automatically. When it comes to emergency power for critical home systems, the standby generator fills in when the utility company struggles to deliver power.

Standby emergency generators are permanently installed appliances that work with an automatic transfer switch. The switch selects utility power during normal operation and standby generator power throughout an outage. It reconnects the utility when services are restored. Both air-cooled and liquid-cooled models are for sale for residential homes, and operate on natural gas or on LP gas (propane). They may be reliable and commence automatically after a power outage without operator intervention to shield the property and family even if the homeowner is away on holiday or at the office a fairly short distance away.

Portable Generators For Emergencies

Portable generators also supply power during emergencies, but require a homeowner to hook them up, start them, and manually switch your home to generator power utilizing a manual transfer switch. Additionally they have to have a steady diet of fuel. A normal installation includes the manually operated transfer switch that connects to a inlet box and to the key service panel. The switch supplies power from the main panel or from the generator into a select group of essential circuits. A heavy-duty cord connects the generator to the inlet box.

A less sophisticated method connects appliances to the generator with extension cords. This works well with many householders, but operating hard-wired appliances including the furnace is usually unattainable.

Emergency generators supply all-important power during emergencies and each home needs to be furnished with an urgent situation power source.

To find out more info, head to: www.Got-Generators.com

Westinghouse Generators and Pressure Washers

Westinghouse Generators & Some of the Lineup of Generators and Power Washers

In 1886, George Westinghouse founded Westinghouse Electric Company and built the first AC power generating plant in Great Barrington, Massachusetts. Their founder already had knowledge of a different type of power: he patented the rotary steam engine in 1865. Since that time, the Westinghouse company has built numerous products from jet engines to light bulbs. Two current products that speak of their roots are the generator and the pressure washer.

Portable Generators

Westinghouse manufactures portable generators rated from 3250 watts through 7000 watts, providing reliable power while at work or in your own home, for everyday use or supply power outage. All of the units run using regular, unleaded gasoline. The engines are protected with automatic shutdown for low oil conditions. All of the portable generators include Westinghouse’s unique VR voltage regulation system for clean, quality power well suited for most electronics.
All of the portable generators include a cpanel which includes four, 20-ampere 120-volt outlets along with a single 30 ampere 120/240-volt twist-lock outlet. Some designs have an included cord allowing you to connect the 120/240-volt outlet with an inlet box or power distribution panel. All outlets are protected by circuit breakers and neutral to ground bonding. An external link to earth ground is required.
Other functions include quiet operation with the Westinghouse Pulse-Flo Muffler system for one of the lowest noise levels in its class. Each unit ships with oil, funnel, along with a tool kit for quick assembly and startup right out of the box. Units furnished with electric start will include a starter battery.
The generators run for 11 to 14 hours at half load, with regards to the height and width of the generator. Fuel consumption by portable electric generators varies with the electrical load and how big the engine.

  • WH3250 – 3250 continuous watts – 3750 surge watts – 14 hour 1/2 load run time – Manual start.
  • WH5500 – 5500 continuous watts – 6750 surge watts – 14 hour 1/2 load run time – Manual start.
  • WH6000S – 6000 continuous watts – 7500 surge watts – 13 hour 1/2 load run time – Electric start – Includes 30-Ampere Power Cord.
  • WH6500E – 6500 continuous watts – 8000 surge watts – 13 hour 1/2 load run time – Electric start.
  • WH7000E – 7000 continuous watts – 8500 surge watts – 11 hour 1/2 load run time – Electric start. WH7000EC is CARB certified for California sale.
  • WH7500E – 7500 continuous watts – 9000 surge watts – 11 hour 1/2 load run time – Electric start.

Power Washers

Westinghouse builds six gasoline-engine-powered power washers with ratings from 2300 to 3000 PSI. All purchases you can use use right out of the box, and includes a top-pressure hose and wand, quick-connect nozzles, engine oil, and detergent/chemical siphon hose. Four standard nozzles include soap dispensing, zero, 25, and 45 degree for various cleaning purposes. All of the models are installed on carts for simple positioning.
The WP 2300 and WP 2500 will include a lightweight gun and wand. Other designs have a stainless steel wand with ergonomic gun.
Westinghouse warrants their power washers for three years.
WP2300 – 2300 PSI – 2.3 Gallons Per Minute (GPM) – 5290 Cleaning Units (CU). EPA and CARB certified emissions to be found in all 50 states.
WP2500 – 2500 PSI – 2.3 GPM – 5750 CU – EPA and CARB certified to be found in all 50 states.
WP2700 – 2700 PSI – 2.2 GPM – 5940 CU – EPA certified to be found in 49 states.  Includes 15 degree nozzle and 30-foot hose.
WP2800 – 2800 PSI – 2.4 GPM – 6720 CU – EPA and CARB certified to be found in all 50 states. Includes 15 degree nozzle and 30-foot hose.
WP3000 – 3000 PSI – 2.4 GPM – 7200 CU – EPA and CARB certified to be found in all 50 states. Includes 15 degree nozzle and 30-foot hose.
WP3000 – 3000 PSI – 2.8 GPM – 8400 CU – EPA and CARB certified to be found in all 50 states. Includes 15 degree nozzle and 30-foot hose.

For more info go to: www.GeneratorPowerforLess.com

Why Kohler Generators are a Great Option for Home Standby Units

Why Kohler Generators make the perfect Option for Home Standby Units

Kohler entered the power generator industry after WW1 after they began building the Kohler Automatic Power & Light Power Plant in 1920 for usage on farms and in other isolated locations. During that time, the rural power grid hadn’t been conceived and also the power plant filled a space that filled an easy-growing requirement of electricity. The generator system was revolutionary for the reason that it started automatically whenever power was needed rather than operating full time.

During World War 2, Kohler supplied generators to U.S. troops around the world in support of the world war 2 effort. After the war, they built standby emergency power generators for hospitals, businesses and government buildings that needed a dependable method to obtain standby power―at that point an unusual concept―Kohler had been there with generator items that met the demands of the time.

After their entry into the generator market over 90 in the past, Kohler Power Systems continues to be manufacturing and supplying standby power generators that actually work automatically without human intervention.

Kohler Home Standby Generators

Kohler’s home standby generators supply power once the electric utility fails. Combined with an automated transfer switch, the units standby around the clock to begin and run automatically in the event of a power outage.

In the event the power fails, the generator waits a few seconds so that the outage is not momentary. Then your engine starts and reaches operating speed. The automatic transfer switch disconnects through the utility supply and connects towards the generator. Electricity is restored to selected circuits or even the entire home (based on the transfer switch configuration). In the event the utility line is re-energized, the transfer switch restores utility power to the property. The generator runs for the minute for cooling down, then turns off.

Kohler supplies home standby generators in sizes that vary from 8500 watts to 100kW that fulfill the power needs of perhaps the most luxurious homes and many businesses.

Automatic Transfer Switches

Standby generators require an automatic transfer switch to work automatically. Kohler designs their automatic transfer switches specifically to use their standby generators. They have several unique designs to meet the needs of most homes.

The Intelligent Transfer Switch Load Center combines a primary service panel with an automatic transfer switch that features a sensible load-shedding power management system. The indoor model has room for 40 circuit breakers, the outdoor NEMA 3R model has room for 28. This model can switch the main service panel.

Other transfer switches made by Kohler include 100 to 400 amp models without or with load centers and power management capabilities. Models without load centers can manage utility and generator power for the entire home or just a subpanel, while load center models are created to operate as a subpanel together with the main circuit breaker panel as the source.

Kohler Power Systems Reliability

Kohler has a long reputation for reliable power solutions. Their innovative systems have been providing power both at home and around the world since the 1920s, and they also were one of the primary to provide automatic standby power generators. Their residence standby generators come with an industry-leading warranty that covers their units for 5 years or 2000 hours. The generators can operate for days or even weeks if necessary, and therefore their models are factory tuned to operate on either LP gas or Natural gas, causing them to be efficient and reliable performers who supply utility quality power whenever it is needed.

For more information, please go to: www.Got-Generators.com

Onan Power Generators

Onan Generators

Cummins Onan was founded in 1920 and supplies generators for RVs, boats, commercial, and emergency vehicles, standby power, and portable applications. With past quality and trust that spans greater than 90 years, Cummins Power Generation is often a name you can rely on along with a product you are able to count on to supply power whenever and wherever it may be needed.

RV Generators

Cummins Onan has RV generators operating on gasoline, diesel, or propane (LP gas) in sizes to fit the most demanding needs of motorhomes, including those that have three rooftop air conditioning units.

Diesel generators for RVs range in size from three,200 to 12,500 watts with six models from which to choose. These generators exceed the nation’s Park Service standards for acceptable noise levels using a specially designed enclosure, even under full load. Accessible for maintenance and self diagnostic capabilities make owning and utilizing a diesel RV generator increasingly simple.

Gasoline generators in nine models supply 2800 to 7000 watts of power, including three models that meet California Air Resource Board (CARB) requirements. Onan gasoline generators feature digital power regulation with low noise and vibration, an easy and compact design, exceptional gas mileage, and easy installation.

For SUTs, fifth-wheels {and Type A and C RVs, LP generators provide 2500 to 6500 watts of power. Enclosed mufflers and vibration reducing enclosures keep the generators exceptionally quiet. Other features include digital voltage regulation and easy access for maintenance.

Marine Generators

Small boats, yachts, and ships have serious power requirements, and Onan Marine Generators intensify towards the plate with sixteen Quiet Diesel generators rated from 5 kilowatts through 99 kilowatts. The QD series is certified to satisfy US EPA requirements and have a world-wide network of distributors and dealers.

QD generators from Cummins are self-monitoring and contact the craft’s onboard network. A digital display provides user-friendly information on self diagnostics, engine and alternator operation, and text displays for reports and standing.

The 17kW and greater models can be bought in either single-phase, 120/240-volts, or three-phase units who supply power at 120/208 – 277 volts. Units smaller compared to 17kW offer single-phase current at 120/240 volts.

Commercial Mobile

Maybe the largest distinctive line of Onan Generators are are their Commercial Mobile generators.

Fire and rescue applications frequently use Cummins Onan PTO and hydraulic generators which use less space than comparable diesel generators. Their Protec PTO generators supply 15,000 to 35,000 watts of power, however the Commercial HG series of hydraulic models can generate 6000 to 25,000 watts of power.

Seven Commercial Quiet Diesel models have rated outputs from 5000 to 12,000 watts. Applications where noise is a lesser amount of a problem can use the Commercial Standard Diesel, with 7500, 10,000 and 20,000 watt models. Each of the diesel generators offer exceptional reliability, reduced vibration, and two year, 2000 hour warranties.

Commercial Quiet Gas propane-powered generators sized from 2500 to 6500 watts supply quality power with reduced noise levels, easy servicing, and digital voltage regulation for lightweight and compact installations. The Quiet Gas line also may include gasoline-powered generators from 2800 to 7000 watts.

Residential Standby

Residential standby generators supply electricity to homes throughout a power outage. Onan offers 13 and 20kW air-cooled models to meet the requirements of all homes, and 20kW to 100kW liquid-cooled generators that will supply the most power hungry luxury homes with electrical energy in an outage. Cummins Onan standby generators are powered by either LP gas (propane) or gas.

Standby generators require a mechanical transfer switch, so when followed by a ATS panel from Cummins Power Generation, their standby generators are fully automatic, supplying power and protecting homes regardless if the homeowner is not present. Cummins Onan standby generators feature digital voltage and frequency regulation to deliver utility quality power.

For more info go to: www.Got-Generators.com

14kw Standby Generator Comparison

14kw Standby Generator Comparison

Once the utility power goes out, standby generators supply backup emergency power during the entire power outage. Whether a major hurricane or possibly a fast-moving local thunderstorm, power outages may last some hours, weekly, or so long as 30 days or even more. Using a availability of standby power from your home generator, residents can stay within their homes instead of seeking shelter elsewhere.

Home standby generators operate automatically and therefore are permanently attached to the home’s electrical system with an automatic transfer switch that is certainly usually supplied by the generator’s manufacturer. The switch and generator controller communicate. Once the power goes out, the generator starts and the transfer switch connects the property to the generator and disconnects it from the utility company. After utility power is restored, the connections are reversed and the generator closes.

Standard Features

Most 14kW standby generator manufacturers offer similar features along with their own make of extra functionality. The engines use a fully pressurized lubrication system just like that in cars and can shut down for low oil pressure or high engine temperature. All of them run the generator by taking exercise cycles to help keep the generator lubricated and stop seals from drying out. After operating under load, they operate for any short, no-load cool-down period.

Utility power is mostly clean and also clear of excessive noise. The AC frequency is steady and unvarying, and the voltage stays within a certain range, rarely falling below 108 volts and not exceeding 125 volts. Standby 14kW generators meet and frequently exceed precisely the same requirements and still provide utility-quality power, even when the loads change frequently or while starting large, heavy-duty motors.

Continuous Power

Standby generators are rated by the quantity of continuous power they can supply, although not all supply the rated continuous power on all fuels. Kohler Power Systems and Generac Power Systems are a couple of manufactures of 14-kilowatt standby generators that operate on LP or natural gas.

Some manufacturers derate their multi-fuel generators when operating on natural gas because natural gas contains about ten % less energy than propane. An engine that can be powered by propane probably will run perfectly on gas with a few adjustments, but because the gas has less energy, the engine cannot create precisely the same power.

Remote Operation

Generac offers Mobil Link as an optional accessory. It uses cellular a text message system to communicate with an online-based dashboard that owners have access to everywhere with a net connection, bringing the Generac14kW standby generator controller to tcomputers around the globe. Status sms are sent to cellphone accounts. A digital cellphone connection with text messages is needed at the 14kW generator installation site.

Kohler’s On Cue Remote Management Systems allows keepers to control their 14kW standby generator from around the globe. Status messages can be mailed to dealers, owners, or both so that maintenance is carried out if required and problems dealt with before they result in a generator to fail. Users can easily see real-time status, see and clean fault codes, manage generator performance, and review generator history. It provides for operation of multiple generators from just one account. The On-Cue Store requires Windows XP, Vista, Windows 7 or Windows 8 and generator connection to the internet.

Warranty

Kohler covers their 14kW standby generators using a consumer warranty of five years or 2000 hours for standby operation when reliable on-grid utility power can be acquired, and includes labor through the first two years after installation. For off-grid applications where utility power isn’t reliable or available, the warranty covers parts for 18 months or 1000 hours.

Generac’s 14Kw standby generator carries a 5 year, 2000 hour limited consumer warranty for on-grid applications. Off-grid applications are not covered and can void the warranty. Comprehensive parts, labor, and mileage are covered for the first two years, parts through the third year, and limited coverage of the engine block and alternator through the fourth and fifth years.

For more info go to: www.NPSGenerac.com

Cummins Onan Cold Weather Package

Cummins Onan Cold Weather Package

Cummins Onan standby generators come in several packages that include various automatic transfer switches and winter packages. Standby generators from Cummins Onan operate automatically when the utility power is interrupted plus they are associated with an automated transfer switch.

Winter packages allow the generator engine to start with less effort during winter, providing more reliable operation under harsh, cold weather conditions.

Cummins Onan Standby Generators

Cummins is really a trusted name in power generation, and standby generators aren’t any exception. Home standby units for emergency power are the 20-kilowatt and 13-kilowatt air-cooled models, along with the 20 kilowatt liquid-cooled machines.

Cummins Power Generation combines their residential standby generators with assorted automatic transfer switches to offer the demands of most home standby customers with utility-quality energy that meets the requirements of the most sensitive of electronics. The generators come with a 5-year, 2000 hour limited consumer warranty.

Cold Weather Equipment

Cummins recommends adding cold-weather accessories to use in climates where temperatures drop to zero degrees Fahrenheit or lower.

A breather heater warms the engine breather tube in order to avoid ice build up during cold weather. It plugs into a cold weather kit (available separately) or into any winter equipped generator. The breather heater is recommended to be used in environments where temperatures drop below zero.

The battery blanket warmer is a flexible heater that wraps round the battery it warm when temperatures drop below -10 degrees. A separate 120-volt outlet is required to turn on the heater.

Winter kits feature an engine oil heater and an alternator dryer. The engine oil heater allows easier starting keeping the oil warm and fluid, and permits the lubrication system to deliver oil faster following your engine starts. Alternator dryers keep frost from accumulating on the alternator.

20-Kilowatt Cold-Weather Packages

Four 20-kilowatt winter packages combine cold-weather equipped generators with automatic transfer switches. The 20kW standby generator packages may start and manage a 5-ton air conditioning unit and possess fully automatic power management capability.

The automatic transfer switches are generally 100-amp or 200-amp, service-entrance-rated automatic transfer switches that include whole-house-power management capability and 2-amp battery chargers, all inside a NEMA 3R enclosure rated for outdoor installation. Also included are an inside wireless monitor and internet monitoring with email notifications.

The RS20-C150 comes with the 100-amp ATS, even though the RS20-C250 gets the 200 amp model. These generator packages are US EPA and CARB certified for emissions.

For ease of installation, Cummins Onan includes two, 100-foot installation harnesses with all RS20-C1100 and RS20-2100. The C1100 includes the 100-amp transfer switch the C2100 with all the 200-amp ATS. US EPA emissions only. Not for sale in California.

13-Kilowatt Cold-Weather Packages

The 13-kilowatt standby generator packages from Cummins Onan include five of the latest models . All include indoor wireless monitors and remote internet monitoring with email updates and therefore are 49 state compliant for US EPA emission standards.

Model 13GSBA-6711A is really a standby generator only equipped for cold weather operation.

Packages that include the automatic transfer switches would be the RS13-150, RS13-250, RS13-C1100, and RS13-C2100. The transfer switches are service entrance, NEMA 3R rated for outdoor installation and built with the two-amp 12v charger and whole-house-power management.

The RS13-C150 has a 100-amp switch and includes two, 50-foot wiring harnesses. The RS13-250 includes the 200-amp switch as well as the two 50-foot wiring harnesses.

The RS13-C1100 with the 100-amp switch and the RS 13-C2100 with 200-amp switch each come with two, 100-foot wiring harnesses.

For more info go to: www.Got-Generators.com